HVACFAULTS
GOODMAN DIAGNOSTIC REFERENCE SINGLE RED LED — FLASH CODES DOC GOODMAN-2-FLASHES

Goodman furnace: Pressure Switch Stuck Closed

YOUR LIGHT: 2 FLASHES — MATCH IT ABOVE

Professional repair

What does 2 flashes mean on a Goodman furnace? The control sees the pressure switch closed while the induced-draft blower is OFF — it waits until the fault clears. Officially: a faulty pressure switch or shorted wiring.

GOOD NEWS: THE FIRST CHECKS ARE FREE AND TAKE MINUTES.

Try these first — in this order

Only check for loose or pinched wires at the switch.

Still showing the code? See every cause ↓ Get repair quotes near you

Low-voltage circuit diagnosis is a tech job. DIY part cost: $25–60 — a pro visit for this class of fault typically runs $150–350.

What causes it (in order of likelihood)

  1. Faulty pressure switch (official first cause) TECH
  2. Short in the pressure-switch wiring TECH

Parts referenced by this code

Pressure Switch
$25–60 · Model-specific — match to your unit’s parts list

Always match parts against your model's parts list — part numbers vary within a series.

Applies to

GMS8 · GDS8 · GHS8 · GMSS96 · GMH8 · GDH8

Different Goodman generations use different code maps. If your series isn't listed, don't assume this meaning — check your blower-door label.

Verified against Goodman GMS8/GDS8/GHS8 Service Manual (RS6612006), p.42-43 — “two short flashes followed by a longer pause”

Verified against Goodman GMSS96 Service Manual, p.32

Last verified 2026-07-06 · how we verify